
Apollo™ 4ALF62AC3 DCDALF4A Type 2 Backflow Preventer, 4 in Nominal, Outside Stem and Yoke Flanged End Style, 304 Stainless Steel Body, Dual Check, Domestic
CBPN:247219
UPC:670750557712
MPN:4ALF62AC3
DESCRIPTION
Apollo™ 4ALF62AC3, Backflow Preventer, Type 2, Series: DCDALF4A, 4 in Nominal, Outside Stem and Yoke Flanged End Style, 175 psi Pressure, 33 to 140 deg F, Dual Check Backflow, Media: Water, 304 Stainless Steel Body, Domestic
The 2-1/2 in to 12 in Double Check Detector Assembly shall be an Apollo™ Model DCDALF 4A or DCDA2LF 4A. The assembly shall be manufactured in America and carry a 5-year Apollo™ factory warranty. The TriForce™ center-stem guided check valves shall feature reversible silicone rubber seat discs. The check valves shall be held in place by stainless steel snap-in retainers (2-1/2 in to 6 in) or stainless steel studs and nuts (8 in to 12 in). Access to the check valves shall be by an Apollo™ quick-connect stainless steel coupling (2-1/2 in to 6 in) or grooved couplings (8 in to 12 in). The bodies shall be domestic stainless steel in 22-1/2 in to 8 in sizes and FDA epoxy-coated ductile iron in 10 in and 12 in sizes. The assembly consists of a mainline double check valve with a Type 2 bypass (Type 1 optional) consisting of a lead free single check (SCV) and meter bypassing the mainline second check to prevent backflow while accurately measuring all flows up to 2 gpm while the mainline 2nd check remains closed. Assemblies with the optional Type 1 bypass consist of a lead free double check valve and meter which bypass both mainline checks and accurately meter all flows up to 2 gpm with the mainline checks closed. The Apollo™ lead free domestic ball valve test cocks shall have stainless steel handles. The pressure drop across the assembly shall be documented by an independent laboratory. The assembly shall prevent contamination of the potable water supply due to back-siphonage or backpressure from substances that are non-health hazards.
Apollo™ 4ALF62AC3 DCDALF4A Type 2 Backflow Preventer, 4 in Nominal, Outside Stem and Yoke Flanged End Style, 304 Stainless Steel Body, Dual Check, Domestic
CBPN:247219
MPN:4ALF62AC3
UPC:670750557712
DESCRIPTION
Apollo™ 4ALF62AC3, Backflow Preventer, Type 2, Series: DCDALF4A, 4 in Nominal, Outside Stem and Yoke Flanged End Style, 175 psi Pressure, 33 to 140 deg F, Dual Check Backflow, Media: Water, 304 Stainless Steel Body, Domestic
The 2-1/2 in to 12 in Double Check Detector Assembly shall be an Apollo™ Model DCDALF 4A or DCDA2LF 4A. The assembly shall be manufactured in America and carry a 5-year Apollo™ factory warranty. The TriForce™ center-stem guided check valves shall feature reversible silicone rubber seat discs. The check valves shall be held in place by stainless steel snap-in retainers (2-1/2 in to 6 in) or stainless steel studs and nuts (8 in to 12 in). Access to the check valves shall be by an Apollo™ quick-connect stainless steel coupling (2-1/2 in to 6 in) or grooved couplings (8 in to 12 in). The bodies shall be domestic stainless steel in 22-1/2 in to 8 in sizes and FDA epoxy-coated ductile iron in 10 in and 12 in sizes. The assembly consists of a mainline double check valve with a Type 2 bypass (Type 1 optional) consisting of a lead free single check (SCV) and meter bypassing the mainline second check to prevent backflow while accurately measuring all flows up to 2 gpm while the mainline 2nd check remains closed. Assemblies with the optional Type 1 bypass consist of a lead free double check valve and meter which bypass both mainline checks and accurately meter all flows up to 2 gpm with the mainline checks closed. The Apollo™ lead free domestic ball valve test cocks shall have stainless steel handles. The pressure drop across the assembly shall be documented by an independent laboratory. The assembly shall prevent contamination of the potable water supply due to back-siphonage or backpressure from substances that are non-health hazards.
Specifications
Item Features
- Easy maintenance no special tools required
- Low pressure loss as documented by an independent laboratory
- Center-stem guided Triforce check valves
- Snap-in check retainers
- Meter type - cfm